Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
pick-and-place [2020/10/12 22:11]
arthur
pick-and-place [2020/10/12 23:21]
arthur
Line 76: Line 76:
  
 Todo: Here add the right configuration to be able to use the temperature-control module to directly read ADCs, bypassing the actual thermistor math for direct/linear reading. This will be added as soon as Shai gives me his configuration, which should be soon I expect. Todo: Here add the right configuration to be able to use the temperature-control module to directly read ADCs, bypassing the actual thermistor math for direct/linear reading. This will be added as soon as Shai gives me his configuration, which should be soon I expect.
 +
 +<code>
 +# VACUUM SENSING
 +
 +# LEFT Nozzle Vacuum configuration
 +
 +temperature_control.vac_n1.enable                 true             # Whether to activate this ( "hotend" ) module at all.
 +
 +temperature_control.vac_n1.sensor                   ad8495           #
 +
 +temperature_control.vac_n1.ad8495_pin             0.23             # Pin for the thermistor to read
 +
 +temperature_control.vac_n1.ad8495_offset          0                #
 +
 +temperature_control.vac_n1.heater_pin             nc               # Pin to controls the heater, nc if a read only thermistor.                                                   # thermistor is being defined
 +
 +temperature_control.vac_n1.readings_per_second      500                # How many times per second to read temperature from the sensor.
 +
 +temperature_control.vac_n1.get_m_code               104                  # Calling this M-code will return the current temperature.
 +
 +temperature_control.vac_n1.designator             VAC              # Designator letter for this module
 +
 +temperature_control.vac_n1.rt_curve               20.0,220,120,6000,220,120000
 +
 +# RIGHT Nozzle Vacuum configuration
 +
 +temperature_control.vac_n2.enable                 true             # Whether to activate this ( "hotend" ) module at all.
 +
 +temperature_control.vac_n2.sensor                   ad8495           #
 +
 +temperature_control.vac_n2.ad8495_pin             0.24             # Pin for the thermistor to read
 +
 +temperature_control.vac_n2.ad8495_offset          0                #
 +
 +temperature_control.vac_n2.heater_pin             nc               # Pin to controls the heater, nc if a read only thermistor.
 +
 +temperature_control.vac_n2.readings_per_second      500              # How many times per second to read temperature from the sensor.
 +
 +temperature_control.vac_n2.get_m_code               105                  # Calling this M-code will return the current temperature.
 +
 +temperature_control.vac_n2.designator             VAC              # Designator letter for this module
 +
 +temperature_control.vac_n2.rt_curve               20.0,220,120,6000,220,120000
 +
 +</code>
  
 == Servos as axes == == Servos as axes ==